Abstract: 

We aimed to review the role of different types of imaging (computed tomography [СТ], ultrasonography [US], magnetic resonance imaging [MRI]) in measuring the optic nerve diameter (OND) and optic nerve sheath diameter (ONSD) in adults and the potential advantages and limitations of each modality. A literature search was carried out using ResearchGate, Saudi Digital Library, Google Scholar, and Mendeley databases between 2010 and 2021 (papers presented in English) with the keywords “computed tomography,” “magnetic resonance imaging,” “ultrasonography,” “optic nerve sheath diameter,” and “optic nerve diameter.” Of the 60 articles analyzed, 42 were included in the review. Compared to ONSD, the evidence for OND appeared to be more limited. After comparing all three imaging modalities (CT, MRI, and US), we concluded that for the most accurate measurements of ONSD we should be using MRI (range: 4.0–6.0 mm). CT (range: 4.4–6.7 mm) would provide the second most exact measurements after MRI. Although CT and MRI provide the most consistent and accurate measurements, ultrasound is more commonly used (ONSD range: 3.4–7.7 mm) due to it’s being non-invasive, easy to use, and easily available anywhere, from big hospitals to small clinics, unlike CT and MRI. All three imaging modalities can provide good measurements, and hopefully, soon ultrasound will be as accurate as MRI in measuring the optic nerve.

Keywords: 
optic nerve • optic nerve sheath diameter • computed tomography • ultrasonography • magnetic resonance imaging
References: 
  1. Weber AL, Caruso P, Sabates NR. The optic nerve: radiologic, clinical, and pathologic evaluation. Neuroimaging Clinics. 2005 Feb 1;15(1):175-201. doi: 10.1016/j.nic.2005.02.011.
  2. Chen H, Ding GS, Zhao YC, Yu RG, Zhou JX. Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults. BMC neurology. 2015 Dec;15(1):1-6. doi:10.1186/s12883-015-0361-x
  3. Watanabe A, Kinouchi H, Horikoshi T, Uchida M, Ishigame K. Effect of intracranial pressure on the diameter of the optic nerve sheath. Journal of Neurosurgery. 2008 Aug 1;109(2):255-8. doi: 10.3171/JNS/2008/109/8/0255.
  4. Munawar K, Khan MT, Hussain SW, Qadeer A, Shad ZS, Bano S, Abdullah A. Optic nerve sheath diameter correlation with elevated intracranial pressure determined via ultrasound. Cureus. 2019 Feb 27;11(2). doi: 10.7759/cureus.4145
  5. Atlas SW, Grossman RI, Hackney DB, Goldberg HI, Bilaniuk LT, Zimmerman RA. STIR MR imaging of the orbit. American journal of neuroradiology. 1988 Sep 1;9(5):969-74. doi: 10.2214/ajr.151.5.1025
  6. Rush B, Wormsbecker A, Berger L, Wiskar K, Sekhon MS, Griesdale DE. Optic nerve sheath diameter on computed tomography not predictive of neurological status post-cardiac arrest. CJEM. 2017 May;19(3):181-185. doi: 10.1017/cem.2016.348.
  7. Al-Tameemi HN, Helel NM. Agreement Between Computed Tomography And Magnetic Resonance Imaging In Measuring Optic Nerve Sheath Diameter. Global Journal of Health Science. 2018;10(4). doi:10.5539/gjhs.v10n4p22
  8. Itanyi UD,  Leslie AM,  Chukwuegbo JN. Normal Values of Optic Nerve Sheath Diameter on Computed Tomography and effect of Raised Intracranial Pressure on Head Injury Patients in North Central Nigeria. Journal of Advances in Medicine and Medical Research. 2021. DOI: 10.9734/jammr/2021/v33i1430966
  9. Kancherla S, Kohler WJ, van der Merwe Y, Chan KC. In Vivo Evaluation of the Visual Pathway in Streptozotocin-Induced Diabetes by Diffusion Tensor MRI and Contrast Enhanced MRI. PLoS One. 2016 Oct 21;11(10):e0165169. doi: 10.1371/journal.pone.0165169. 
  10. Mncube SS, Goodier MD. Normal measurements of the optic nerve, optic nerve sheath and optic chiasm in the adult population. SA J Radiol. 2019 Nov 5;23(1):1772. doi: 10.4102/sajr.v23i1.1772.
  11. Benevento JD, Garcia JP, Baxter AB, Garcia PM, Holliday RA, Rosen RB. Optic nerve measurements in normal human eyes by MRI. Investigative Ophthalmology & Visual Science. 2004 May 1;45(13):2398.
  12. Kim DH, Jun JS, Kim R.   Measurement of the Optic Nerve Sheath Diameter with Magnetic Resonance Imaging and Its Association with Eyeball Diameter in Healthy Adults.   J Clin Neurol. 2018 Jul;14(3):345-350 doi: 10.3988/jcn.2018.14.3.345.
  13. Vaiman M, Abuita R, Bekerman I. Optic nerve sheath diameters in healthy adults measured by computer tomography. Int J Ophthalmol. 2015 Dec 18;8(6):1240-4. doi: 10.3980/j.issn.2222-3959.2015.06.30.
  14. Gupta V, Prabhakar A, Yadav M, Khandelwal N. Computed tomography imaging-based normative orbital measurement in Indian population. Indian J Ophthalmol. 2019 May;67(5):659-663. doi: 10.4103/ijo.IJO_1187_18. 
  15. Li YM, Zhou HM, Xu XY, Shi HS. Research progress in MRI of the visual pathway in diabetic retinopathy. Current Medical Science. 2018 Dec;38(6):968-75. doi: 10.1007/s11596-018-1971-5.
  16. Pircher A, Montali M, Berberat J, Remonda L, Killer HE. Relationship between the optic nerve sheath diameter and lumbar cerebrospinal fluid pressure in patients with normal tension glaucoma. Eye (Lond). 2017 Sep;31(9):1365-1372. doi: 10.1038/eye.2017.70. 
  17. Jaggi GP, Miller NR, Flammer J, Weinreb RN, Remonda L, Killer HE. Optic nerve sheath diameter in normal-tension glaucoma patients. Br J Ophthalmol. 2012 Jan;96(1):53-6. doi: 10.1136/bjo.2010.199224. 
  18. Ko TY, Cheng JH, Luk YS, Khoo JL. Normative Measurements of Orbital Structures in the Hong Kong Population. Hong Kong Journal of Radiology. 2021 Mar 1;24(1):31. doi: 10.12809/hkjr2117133
  19. Giger-Tobler C, Eisenack J, Holzmann D, Pangalu A, Sturm V, Killer HE, Landau K, Jaggi GP. Measurement of Optic Nerve Sheath Diameter: Differences between Methods? A Pilot Study. Klin Monbl Augenheilkd. 2015 Apr;232(4):467-70. doi: 10.1055/s-0035-1545711. 
  20. Ko SB. Optic Nerve Sheath Diameter On Brain Magnetic Resonance Imaging: A Single Center Study. Journal of Neurocritical Care. 2015 Jun 30;8(1):16-24. doi:10.18700/jnc.2015.8.1.16
  21. Watcharakorn A, Witayapiboon S,  Mingkwansook V. Measurement of Normal Diameter of Optic Nerve and Optic Nerve Sheath Using MRI. Science & Technology Asia. 2921;26 (3, July-September):167-173
  22. EROĞLU  SE, YÖNAK H, İSLAM MM, GÜNER G, AKSEL G, SAKCI Z. Determination of normal values of optic nerve sheath diameter in Turkish adult population using magnetic resonance imaging. J Exp Clin Med 2021; 38(4): 545-549. doi: 10.52142/omujecm.38.4.27
  23. Chandrappa A, Raman R, Rashmi RD, Shetty SP. Normal Optic Nerve Sheath Diameter and its Relation with Orbital Diameter on 3T MRI: A Cross-sectional Study. Int J Anat Radiol Surg. 2017;6(2):46-52. doi: 10.7860/IJARS/2017/24843:2265
  24. Maude RR, Amir Hossain M, Hassan MU, Osbourne S, Sayeed KL, Karim MR, Samad R, Borooah S, Dhillon B, Day NP, Dondorp AM. Transorbital sonographic evaluation of normal optic nerve sheath diameter in healthy volunteers in Bangladesh. PloS one. 2013 Dec 2;8(12):e81013.  doi: 10.1371/journal.pone.0081013
  25. Goeres P, Zeiler FA, Unger B, Karakitsos D, Gillman LM. Ultrasound assessment of optic nerve sheath diameter in healthy volunteers. J Crit Care. 2016 Feb;31(1):168-71. doi: 10.1016/j.jcrc.2015.10.009. 
  26. Garcia JP Jr, Garcia PM, Rosen RB, Finger PT. Optic nerve measurements by 3D ultrasound-based coronal "C-scan" imaging. Ophthalmic Surg Lasers Imaging. 2005 Mar-Apr;36(2):142-6.
  27. Bäuerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A. Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol. 2013 Dec 1;13:187. doi: 10.1186/1471-2377-13-187.
  28. Anas I. Transorbital sonographic measurement of normal optic sheath nerve diameter in nigerian adult population. Malays J Med Sci. 2014 Sep-Oct;21(5):24-9. 
  29. Chan PY, Mok KL. Transorbital sonographic evaluation of optic nerve sheath diameter in normal Hong Kong Chinese adults. Hong Kong Journal of Emergency Medicine. 2008 Oct;15(4):197-204. doi: 10.1177/102490790801500402
  30. Avci M, Kozaci N, Komut E, Komut S, Caliskan G, Tulubas G. The Measurement of Elderly Volunteers' Optic Nerve Sheath Diameters by Ocular Ultrasonography. Medicina (Kaunas). 2019 Jul 27;55(8):413. doi: 10.3390/medicina55080413. 
  31. Ertl M, Knüppel C, Veitweber M, Wagner A, Pfister K, Wendl C, Baldaranov D, Beck J, Linker RA, Schlachetzki F. Normal Age- and Sex-Related Values of the Optic Nerve Sheath Diameter and Its Dependency on Position and Positive End-Expiratory Pressure. Ultrasound Med Biol. 2020 Dec;46(12):3279-3285. doi: 10.1016/j.ultrasmedbio.2020.08.025. 
  32. Asghar A, Hashmi M, Hussain A. Optic nerve sheath diameter evaluated by transorbital sonography in healthy volunteers from Pakistan. Anaesthesia Pain & Intensive Care. 2015;19(3):282-286.
  33. Rehman H, Khan MS, Nafees M, Rehman AU, Habib A. Optic Nerve Sheath Diameter on Sonography in Idiopathic Intracranial Hypertension Versus Normal. J Coll Physicians Surg Pak. 2016 Sep;26(9):758-60. 
  34. Wang L, Feng L, Yao Y, Wang Y, Chen Y, Feng J, Xing Y. Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population. PLoS One. 2015 Feb 9;10(2):e0117939. doi: 10.1371/journal.pone.0117939. 
  35. Soldatos T, Karakitsos D, Chatzimichail K, Papathanasiou M, Gouliamos A, Karabinis A. Optic nerve sonography in the diagnostic evaluation of adult brain injury. Crit Care. 2008;12(3):R67. doi: 10.1186/cc6897.
  36. Ballantyne SA, O'Neill G, Hamilton R, Hollman AS. Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. Eur J Ultrasound. 2002 Oct;15(3):145-9. doi: 10.1016/s0929-8266(02)00036-8. 
  37. Lochner P, Coppo L, Cantello R, Nardone R, Naldi A, Leone MA, Brigo F. Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults. J Ultrasound. 2014 Nov 20;19(1):41-5. doi: 10.1007/s40477-014-0144-z.
  38. Kim DH, Jun JS, Kim R. Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers. Sci Rep. 2017 Nov 21;7(1):15906. doi: 10.1038/s41598-017-16173-z. P
  39. Savi de Tové KM, Akanni D, Kiki M, Adjadohoun S, Lokossou G, Yèkpè-Ahouansou P, Biaou O, Boco V. Sonographic Measurement of the Optic Nerve Sheath Diameter (ONSD) and Eyeball Transversal Diameter (ETD) in Benin Healthy African Adults. Open Journal of Radiology. 2020;10:149-158. doi: 10.4236/ojrad.2020.103015
  40. Shokoohi H, Pyle M, Kuhl E, Loesche MA, Goyal A, LeSaux MA, Boniface KS, Taheri MR. Optic Nerve Sheath Diameter Measured by Point-of-Care Ultrasound and MRI. J Neuroimaging. 2020 Nov;30(6):793-799. doi: 10.1111/jon.12764.
  41. Kalantari H, Jaiswal R, Bruck I, Matari H, Ghobadi F, Weedon J, Hassen GW. Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging. Am J Emerg Med. 2013 Nov;31(11):1595-7. doi: 10.1016/j.ajem.2013.07.028. 
  42. Steinborn M, Fiegler J, Kraus V, Denne C, Hapfelmeier A, Wurzinger L, Hahn H. High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance. Ultraschall Med. 2011 Dec;32(6):608-13. doi: 10.1055/s-0029-1245822. 

Download Article
Received June 6, 2022.
Accepted July 17, 2022.
©2022 International Medical Research and Development Corporation.