A Pressure Sensor for an Electrode System in Transpalpebral Rheoophtalmography

Dmitry M. Shamaev, Petr V. Luzhnov, Elena N. Iomdina

 
International Journal of Biomedicine. 2018;8(2):159-161.   
DOI: 10.21103/Article8(2)_OA11
Originally published June 15, 2018

Abstract: 

A method of pressure registration in transpalpebral rheoophtalmography (TP-ROG) is proposed. Possible construction solutions of this method are presented, including sensor types and their technical parameters. One such solution (a resistive pressure sensor) was incorporated in a TP-ROG electrode system. The system was used to measure the sensitivity and linearity of this pressure sensor.

Keywords: 
transpalpebral rheoophtalmography • bioimpedance • electrode system • pressure sensor • eye
References: 
  1. Bettelheim H. [Oculorheography. A method for studies in intraocular circulation]. Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1971;183(1):1-21. [Article in German]. PubMed
  2. Lazarenko VI, Kornilovskiĭ IM, Il'enkov SS, Polyntsev LA, Komarovskikh EN, Alekseeva LL, et al.  [Our method of functional rheography of eye]. Vestnik Oftal’mologii. 1999;115(4):33-37. [Article in Russian]. PubMed
  3. Avetisov ES, Katsnel'son LA, Savitskaia NF. [Rheocyclographic examinations in myopia]. Vestnik Oftal’mologii. 1967; 80(3): 3-7. [Article in Russian]. PubMed
  4. Lazarenko VI, Komarovskikh EN. Results of the examination of hemodynamics of the eye and brain in patients with primary open-angle glaucoma. Vestn Oftalmol. 2004;120(1):32-36. [Article in Russian]. PubMed
  5. Luzhnov PV, Shamaev DM, Iomdina EN, Tarutta EP, Markosyan GA, Shamkina LA, et al. [Transpalpebral tetrapolar reoophtalmography in the assessment of parameters of the eye blood circulatory system. Vestn Ross Akad Med Nauk. 2015;70(3):372-7. PubMed
  6. Shamaev DM, Luzhnov PV, Pika TO, Iomdina EN, Kleyman AP, Sianosyan AA. Applying Transpalpebral Rheoophthalmography to monitor effectiveness of the treatment of patients with glaucoma. International Journal of Biomedicine. 2016;6(4):287-289. Google Scholar
  7. Shamaev DM, Luzhnov PV, Iomdina EN. (2018) Modeling of ocular and eyelid pulse blood filling in diagnosing using transpalpebral rheoophthalmography. In: Eskola H, Väisänen O, Viik J, Hyttinen J. (eds) EMBEC & NBC 2017. EMBEC 2017, NBC 2017. IFMBE Proceedings, vol 65. Springer, Singapore. Google Scholar
  8. Luzhnov PV, Shamaev DM, Iomdina EN, Markosyan GA, Tarutta EP, Sianosyan AA. (2018) Using quantitative parameters of ocular blood filling with transpalpebral rheoophthalmography. In: Eskola H, Väisänen O, Viik J, Hyttinen J. (eds) EMBEC & NBC 2017. EMBEC 2017, NBC 2017. IFMBE Proceedings, vol 65. Springer, Singapore. Google Scholar

Download Article
Received April 27, 2018.
Accepted May 18, 2018.
©2018 International Medical Research and Development Corporation.