For citation: Telhaj E, Rrakaqi B, Xhafa B, Elezaj N, Kaçiu Y. Algorithmical Applications in the XiO Treatment Plan Based on Dosimetric Measurements. International Journal of Biomedicine. 2025;15(1):162-166. doi:10.21103/Article15(1)_OA18
Originally published March 5, 2025
The beam modeling of the linear accelerator is performed based on dosimetric measurements by including the data obtained for the absorbed dose in water at a depth of 10cm (D10), percent depth doses, and geometric symmetry of the fields. The results obtained for photon beams with the energy 6MV and 18MV are placed in a database of the treatment planning system (XiO). Then, it becomes a reference system for modeling the photonic beams with high energy and creating patient treatment plans. The field modeling and calculation of the dose that should be given to the patient are done by precise dosimetric measurements.
- Palmans H, Nafaa L, De JJ, Gillis S, Hoornaert MT, Martens C, Piessens M, Thierens H, Van der Plaetsen A, Vynckier S. Absorbed dose to water based dosimetry versus air kerma based dosimetry for high-energy photon beams: an experimental study. Phys Med Biol. 2002 Feb 7;47(3):421-40. doi: 10.1088/0031-9155/47/3/305. PMID: 11848121.
- Nordstrom F. Quality Assurance in Radiotherapy - Development and evaluation of new tools for improved patient safety. Lund University, 2012
- International Commission on Radiation Units and Measurements (2000): Dosimetry of High-Energy Photon Beams Based on Standards of Absorbed Dose to Water, ICRU Report Nr. 64, Bethesda, MD. ICRU: 1-450
- Khan MF. The Physics of Radiation Therapy, Fourth Edition, 5 – 67, Minneapolis, Minnesota, 2010.
- International Atomic Energy Agency, Technical Report Series No. 398: Absorbed Dose Determination in External Beam Radiotherapy. An International Code of Practice for Dosimetry Based Standards of Absorbed Dose to Water, IAEA, Vienna, 2000.
- Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R, Rogers DW. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999 Sep;26(9):1847-70. doi: 10.1118/1.598691. PMID: 10505874.
- Barret A, Dobbs J, Morris S, Roques T. Practical Radiotherapy Planning, Fourth Edition, London, 2009.
- Europian Society for Therapeutic Radiology and Oncology: Monitor Unit Calculation for High Energy Photon Beams, Practical Examples, Booklet No.3, 1-521, Belgium, 2001.
- Dutreix A. et al. Monitor unit calculation for high energy photon beams, Physics for Clinical Radiotherapy, Belgium, 1997
- Ahnesjö A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med Phys. 1989 Jul-Aug;16(4):577-92. doi: 10.1118/1.596360. PMID: 2770632.
- Knöös T, Wieslander E, Cozzi L, Brink C, Fogliata A, Albers D, Nyström H, Lassen S. Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations. Phys Med Biol. 2006 Nov 21;51(22):5785-807. doi: 10.1088/0031-9155/51/22/005. Epub 2006 Oct 24. PMID: 17068365.
Download Article
Received November 24, 2025.
Accepted February 26, 2025.
©2025 International Medical Research and Development Corporation.